Material: W2T170249 Unit of Measure #: EA See All PVDF ValidatedThe Evoqua FCPV cartridge is comprised of a 0.2m rated validated, pleated hydrophilic PVDF membrane over a non-woven polypropylene support layer. Code 0, Code 5, and Code 7 configurations are available in 10, 20, 30, and 40-in lengths that are 100% tested in manufacturing to ensure absolute bacteria retention with typical litter reduction of >107/cm2. FCPV Cartridge meet current USP Class VI Biological Tests For Plastics, with a validation certificate available to support the bacteria challenge results. Cartridge contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables. Supported single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates. FCPV Cartridge Filters can be sterilized by autoclaving. Features: Length: 20"Diameter (OD): 2. 75" (6. 6cm)Materials of Construction: Polypropylene caps, core, and cage. PVDF media. Silicon O-Rings Maximum differential pressure @ 25C: 85PSI (5. 5bar)Efficiency rating: 100% absolute Recommended Water Flow Rate: 1. 0GPM per 10" length Single open end with two 2-2-2 style O-Ring end caps, flat closed end (Code 0)
- Length: 20"
- Diameter (OD): 2.75" (6. 6cm)
- Materials of Construction: Polypropylene caps, core, and cage.
- PVDF media
- Silicon O-Rings
- Maximum differential pressure @ 25C: 85PSI (5. 5bar)
- Efficiency rating: 100% absolute R
- ecommended Water Flow Rate: 1.0GPM per 10" length
- Single open end with two 2-2-2 style O-Ring end caps, flat closed end (Code 0)
- EvoquaFCVA 107.6 KB
- All Documentation
The Evoqua FCPV cartridge is comprised of a 0.2m rated validated, pleated hydrophilic PVDF membrane over a non-woven polypropylene support layer. Code 0, Code 5, and Code 7 configurations are available in 10, 20, 30, and 40-in lengths that are 100% tested in manufacturing to ensure absolute bacteria retention with typical litter reduction of >107/cm2. FCPV Cartridge meet current USP Class VI Biological Tests For Plastics, with a validation certificate available to support the bacteria challenge results. Cartridge contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables. Supported single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates. FCPV Cartridge Filters can be sterilized by autoclaving. Features: Length: 20"Diameter (OD): 2. 75" (6. 6cm)Materials of Construction: Polypropylene caps, core, and cage. PVDF media. Silicon O-Rings Maximum differential pressure @ 25C: 85PSI (5. 5bar)Efficiency rating: 100% absolute Recommended Water Flow Rate: 1. 0GPM per 10" length Single open end with two 2-2-2 style O-Ring end caps, flat closed end (Code 0)
- Length: 20"
- Diameter (OD): 2.75" (6. 6cm)
- Materials of Construction: Polypropylene caps, core, and cage.
- PVDF media
- Silicon O-Rings
- Maximum differential pressure @ 25C: 85PSI (5. 5bar)
- Efficiency rating: 100% absolute R
- ecommended Water Flow Rate: 1.0GPM per 10" length
- Single open end with two 2-2-2 style O-Ring end caps, flat closed end (Code 0)
- EvoquaFCVA 107.6 KB
- All Documentation
Description
FCPV cartridges meet current USP Class VI Biological Tests for Plastics, with a validation certificate available to support the bacteria challenge results. Cartridges contain no surfactants or coatings to interfere with your application, and the thermo-plastic construction process minimizes extractables. Supported single layer membrane ensures strength, while exhibiting low pressure drop and exceptionally high flow rates. FCPV cartridge filters can be sterilized by autoclaving.